Meter: insulation resistance; LCD 3,5"; R range: 0÷60MΩ; 0÷10A
| Manufacturer |
PCE INSTRUMENTS |
| Type of meter |
insulation resistance |
| Kind of display used |
LCD 3,5" |
| Measurement |
AC current AC voltage capacitance DC current DC voltage dielectric absorption ratio (DAR) frequency inrush current insulation resistance measurement (by K thermocouple) resistance |
| Resistance measuring range |
0...60MΩ |
| AC voltage measuring range |
0...1kV |
| DC voltage measuring range |
0...1kV |
| DC current measuring range |
0...10A |
| Capacitance measuring range |
0...6mF |
| Frequency measuring range |
40Hz...10kHz |
| Test |
diodes |
| Interface |
Bluetooth |
| Temperature measuring range (with K-type thermocouple) |
-20...1000°C |
| Test voltage |
100V 250V 500V 1kV |
| Conform to the norm |
CAT III 1000V CAT IV 600V |
| Measuring instrument features |
automatic power-off HOLD function memory built-in MIN/MAX function polarization index (PI) and dielelectric absorption ratio (DAR) |
| Standard equipment |
hard case K-type thermocouple test leads ( 2pcs.) user's manual |
| Power supply |
battery AA 1,5V x6 |
| IP rating |
IP65 |
| Dimensions |
215x65x100mm |
| Insulation resistance measuring ranges |
125kΩ...6GΩ |
| Battery/ rechargeable battery |
battery AA 1,5V x6 |
| Measurement memory |
1800 |
| Storage temperature |
-20...60°C |
| Operating temperature |
5...40°C |