Added to cart
View cart
Meter: multifunction; pincers type; Øcable: 45mm; LCD; True RMS
| Manufacturer |
HT INSTRUMENTS |
| Type of meter |
multifunction |
| Kind of meter |
digital pincers type |
| Max. diameter of measured cable |
45mm |
| Kind of display used |
LCD |
| DC current measuring range |
60A 600A 1kA |
| AC current measuring range |
60A 600A 1kA |
| Measuring instrument features |
automatic power-off autoranging HOLD function low battery indicator MIN/MAX function PEAK function REL function |
| DC current measuring accuracy |
±(2% + 8 digit) |
| AC current measuring accuracy |
±(2.2% + 8 digit) |
| DC voltage measuring range |
600mV 6V 60V 600V 1kV |
| DC voltage measuring accuracy |
±(1% + 3 digit) |
| AC voltage measuring range |
6V 60V 600V 1kV |
| AC voltage measuring accuracy |
±(1% + 4 digit) |
| Resistance measuring accuracy |
±(1%+5 digit) |
| True effective value measurement |
True RMS |
| Resistance measuring range |
600Ω 6kΩ 60kΩ 600kΩ 6MΩ 60MΩ |
| Capacitance measuring range |
40nF 400nF 4µF 40µF 400µF 4mF |
| Capacitance measuring accuracy |
±(2.5%+ 5 digit) |
| Frequency measuring range |
99.99Hz 999.9Hz 9.999kHz 60kHz |
| Frequency measuring accuracy |
±(1%+5 digit) |
| Temperature measuring range |
-20...760°C |
| Temperature measurement accuracy |
±(2% + 3°C) |
| Test |
diodes |
| Pollution degree |
2 |
| Dimensions |
252x88x44mm |
| Power supply |
battery 6F22 9V x1 |
| Standard equipment |
adapter for connecting K-type probe to the meter carrying case K-type temperature probe test leads ( 2pcs.) user's manual |
| Measurement |
AC current AC voltage capacitance continuity DC current DC voltage duty cycle frequency resistance temperature |
| Conform to the norm |
CAT III 1000V CAT IV 600V EN 61010-1 EN 61326-1 |
| IP rating |
IP20 |
| Operating temperature |
0...40°C |
| Battery/ rechargeable battery |
battery 6F22 9V x1 |
| Continuity test |
<60Ω |
| Illumination |
yes |
| Bargraph |
yes |