Added to cart
View cart
Benchtop multimeter; LCD TFT 3"; 5,5 digit; True RMS
| Manufacturer |
GW INSTEK |
| Type of meter |
benchtop multimeter |
| Kind of display used |
LCD TFT 3" |
| Display parameters |
5,5 digit |
| True effective value measurement |
True RMS |
| DC voltage measuring range |
200mV 2V 20V 200V 1kV |
| DC voltage measuring accuracy |
±(0.012% + 5 digit) |
| AC voltage measuring range |
200mV 2V 750V |
| AC voltage measuring accuracy |
±(0.2% + 100 digit) |
| DC current measuring range |
20mA 200mA 2A 10A |
| DC current measuring accuracy |
±(0.05% + 5 digit) |
| AC current measuring range |
20...2000mA 10A |
| AC current measuring accuracy |
±(0.5% + 100 digit) |
| Resistance measuring range |
200Ω 2kΩ 20kΩ 200kΩ 2MΩ 10MΩ 100MΩ |
| Resistance measuring accuracy |
±(0.05%+5 digit) |
| Diode test |
0.1mA @6000mV |
| Continuity test |
acoustic indication |
| Measurement |
AC current AC voltage capacitance continuity DC current DC voltage frequency period resistance resistance (2-wire) resistance (4-wire) temperature (external probe required) |
| Interface |
RS232 USB |
| Temperature measuring range (with K-type thermocouple) |
-200...300°C |
| Temperature measuring range (with J-type thermocouple) |
-200...300°C |
| Temperature measuring range (with T-type thermocouple) |
-200...300°C |
| Supply voltage |
100V AC 120V AC 220V AC 240V AC |
| Dimensions |
265x107x302mm |
| Measuring instrument features |
HOLD function MIN/MAX function operates with thermocouple types: J, K, T REL function |
| Standard equipment |
mains cable test leads user's manual |
| Optional equipment |
GDM-TL1 GRA-422 GRA-454 GSC-014 GTL-108A GTL-205 GTL-232 |