BM157 - Meters and AC Clamp Probes

BM157
Description

Meter: power; pincers type; LCD; True RMS AC; VAC: 100mV÷600V; 224g

Specifications
Manufacturer BRYMEN
Type of meter power
Kind of meter pincers type
Measurement AC current
active power
AC voltage
apparent power
DC voltage
energy
frequency
power factor
reactive power
resistance
Kind of display used LCD
True effective value measurement True RMS AC
AC current measuring range 10mA...40A
400A
1kA
AC current measuring accuracy ±(1% + 5 digit)
AC voltage measuring range 100mV...600V
AC voltage measuring accuracy ±(0.5% + 5 digit)
DC voltage measuring range 100mV...600V
DC voltage measuring accuracy ±(0.5% + 5 digit)
Active power measuring accuracy ±(4.5% + 6 digit)
Reactive power measuring accuracy ±(4.5% + 6 digit)
Apparent power measuring accuracy ±(3.5% + 6 digit)
Frequency measuring range 10mHz...5Hz
500Hz
Frequency measuring accuracy ±(0.5%+4 digit)
Resistance measuring range 100mΩ...999.9Ω
Resistance measuring accuracy ±(1%+6 digit)
Harmonic content measuring accuracy ±(1% + 6 digits)
Reactive power measurement 0...600kVAR
Apparent power measurement 0...600kVA
Harmonic content measurement 0...99,99%
Interface RS232 (option)
USB
Power supply battery LR03 AAA 1,5V x2
Measuring instrument features A-lags-V - indicates nature of measured circuit (inductive or capacitive)
automatically selects AAC, VAC, VDC measurement on the basis of measured signal
automatic power-off
autoranging
HOLD function
kWh - measures and records energy consumption in 1- and 3-phase systems with blanced load
PEAK HOLD function for AC measurements
PF - measures total power factor as active to apparent power quotient
THD%-F immediately evaluates harmonic content in measured voltage and current signals
Standard equipment case
test leads
Conform to the norm CAT III 600V
EN 61010
Dimensions 224x78x40mm
Weight with battery 224g
Max. diameter of measured cable 45mm
Illumination yes
Battery/ rechargeable battery battery LR03 AAA 1,5V x2
Bandwidth for AC voltage measurements 40...500Hz
Continuity test acoustic indication
50Ω...250Ω
Power factor measurement 0.01...0.99
Optional equipment KITBRUA-13X software
KITRS232E software
Sampling 1x/s (Hz)
2x/s
Pollution degree 2
Bandwidth for AC current measurements 40...500Hz